The Definitive Guide to perkinelmer autosampler
The Definitive Guide to perkinelmer autosampler
Blog Article
Mixing by aspiration—mixing of sample by aspiration in place of shaking assures homogeneity from the sample and maintains cell viability
The CytKick Max Autosample includes a Increase manner that allows speedier sample processing, and also passive cooling for a few plates/racks. A CytKick Max Accent Kit is integrated which contains four accent plates: two cooling plates and two tube adaptors, as well as a Max dongle vital. A computer is not bundled Together with the autosampler considering that a single is supplied with the cytometer.
To stop probe crashes, which can demand costly probe alternative, the CytKick Max Autosampler instantly performs a probe self-calibration that will help guarantee consistent positioning on the probe within every single well. The self-calibration verifies appropriate functionality from the probe, lowers variability in probe positioning as time passes to avoid failures all through plate runs, and aids strengthen trustworthiness more than the life of the technique.
Compared with other plate loaders that mix samples by shaking, which may not make sure homogeneity in the sample, the CytKick Max Autosampler mixes samples by aspiration and stirring, enabling uniform mixing when preserving sample viability and causing dependable information with CVs under 10% throughout the plate. The CytKick Max Autosampler also has a mild combine mode for fragile cell lines.
The autosampler’s indicator lights and warning programs are intended to ensure that a person who may have walked clear of the procedure can certainly begin to see the technique standing continually.
To keep up program flexibility, the manual sample probe is often available even if the loader perkinelmer autosampler is present, and switching between tubes and plates is detected by using program and won't call for further user intervention.
The CytKick Max Autosampler was created to reduce procedure down time. Automated sampling equipment in many cases are affected by clogging or probe crashes. The Clever Probe, by using a two hundred-micron diameter that is definitely greater than most probes out there while in the industry, minimizes occasions of clogging.
The intuitive program makes it possible for quick Finding out and data Examination. For example, a heat map look at will allow speedy screening and affirmation of samples though the instrument is buying data.
Effortless changeover—no disassembly, no extra QC, no reboot expected for conversion between plates and tubes
The CytKick Max Autosampler has two choices for processing samples inside of a large-throughput natural environment: higher-throughput mode and Improve manner.
Self-calibration from the probe also makes it possible for the autosampler being easily moved, so it can be shared among a number of devices.
The instrument structure and software program had been designed with buyer simplicity-of-use in mind. The CytKick Max Autosampler has fluidic bottles with sensors that tell the user once the fluids must be replaced.
Autocleaning of autosampler is done through the instrument shutdown method as a result no further user actions are required to take care of procedure.
Setting up an experiment with the Attune NxT cytometric program is straightforward. Utilizing a plate layout perspective, buyers can make compensation wells, define instrument options, and recognize samples.